Bug
-
Resolution: Fixed
-
Major
-
None
I am triggering a downstream job and passing CC_BASELINE as a parameter.
Each time the parent view updates and builds properly
from the polling log -
Started on Feb 10, 2012 4:36:22 PM
[CCUCM] Getting baselines for :
[CCUCM] * Stream: ECLPS_Feb12_Int@\ECLPS_PVOB
[CCUCM] * Component: eclps_src@\ECLPS_PVOB
[CCUCM] * Promotion level: ANY
[CCUCM] polling streams: self
The last baseline: baseline:BUILDBOX_2012_02_10_13_19_01@\ECLPS_PVOB:
- Shortname: BUILDBOX_2012_02_10_13_19_01
- PVOB : \ECLPS_PVOB
- Type : Baseline
- Level : BUILT
- Component: component:eclps_src@\ECLPS_PVOB
- Stream : stream:ECLPS_Feb12_Int@\ECLPS_PVOB
- Date : Fri Feb 10 13:19:02 EST 2012
The found baseline: baseline:BUILDBOX_2012_02_10_16_19_01@\ECLPS_PVOB:
- Shortname: BUILDBOX_2012_02_10_16_19_01
- PVOB : \ECLPS_PVOB
- Type : Baseline
- Level : BUILT
- Component: component:eclps_src@\ECLPS_PVOB
- Stream : stream:ECLPS_Feb12_Int@\ECLPS_PVOB
- Date : Fri Feb 10 16:19:03 EST 2012
but the value passed in CC_BASELINE is baseline:BUILDBOX_2012_02_07_14_19_00@\ECLPS_PVOB
That baseline seems to have been the baseline first built by the parent stream.
Is CC_BASELINE updating for other people?