Uploaded image for project: 'Jenkins'
  1. Jenkins
  2. JENKINS-41094

For Unittest++ xml, only the content of the first <system-out> tag of each test case is recognized

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: Minor
    • Resolution: Won't Do
    • Component/s: xunit-plugin
    • Labels:
      None
    • Environment:
      Jenkins 1.653, Linux
    • Similar Issues:

      Description

      For this example xml:

      <?xml version="1.0"?>
      <unittest-results>
        <test suite="Package.Suite" name="Testname">
          <system-out>Some output at the beginning of the test</system-out>
          <failure message="Path/Filename.cxx(1) : Failed for some reason"/>
          <system-out>Some output at the end of the test</system-out>
        </test>
      </unittest-results>
      

      the xUnit plugin shows only the content of the first <system-out> tag.
      The content of the second <system-out> tag "Some output at the end of the test" is not displayed.

        Attachments

          Activity

            People

            • Assignee:
              nfalco Nikolas Falco
              Reporter:
              joe_merten Joe Merten
            • Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: