Started by user Dasari Rakesh (CVC8DZC) Building remotely on UFT_EntAutomation_N1 (uft-ent-n1) in workspace C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller No emails were triggered. [Test_Controller] $ "C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\HpToolsLauncher.exe" -paramfile props28062019112216959.txt "Started..." Run build tests Launcher timeout is 10675199::02:48:05 Controller Polling Interval: 30 seconds PerScenarioTimeout: 00::00:10:00 minutes FileSystemTestRunner timeout is 10675199.02:48:05.4775807 Mc connection info is - Mc HostAddress: , McPort: 8080, Username: , TenantId: , UseSSL: 0, UseProxy: 0, ProxyType: 0, ProxyAddress: , ProxyPort: 0, ProxyAuth: 0, ProxyUser: 1 tests found: D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs ============================================================================ 28/06/2019 11:22:30 Running: D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs Cleaning up the environment... wlrun killed Preparing scenario D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs for execution. Load Generator localhost connected setting scenario result folder to C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\LRR scenario result folder: C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\LRR Starting scenario... Scenario run has started Error: Scenario Execution timeout 00:00:10:00 (d:h:m:s) passed. Scenario D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs ended after 0:10:0. ============================================================================ Analyzing results... closing Controller Controller closed calling analysis report generator executing Analysis launcher with arguments : "C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\LRR\LRR.lrr" "C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\LRA\LRA.lra" "C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\HTML\HTML.html" "C:\Program Files (x86)\Micro Focus\LoadRunner\AnalysisTemplates\Test_test_template\Test_test_template.tem" time for analysis: 00::00:10:00 starting analysis launcher creating analysis COM object creating analysis session analysis session created creating HTML reports HTML reports created loading errors, if any error count: 18 Error(s) report: ID: 0 Name: Action.c(16) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 1 Name: Action.c(16) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 2 Name: Action.c(16) Error -26377 No match found for the requested parameter "c_RequestToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 bytes. The total length of_2 ID: 3 Name: CreateRentalRequest_Regular.c(11) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 4 Name: CreateRentalRequest_Regular.c(11) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 5 Name: CreateRentalRequest_Regular.c(11) Error -26377 No match found for the requested parameter "c_RequetsToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 bytes_5 ID: 6 Name: CreateRentalRequest_UPSAdmin.c(11) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 7 Name: CreateRentalRequest_UPSAdmin.c(11) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 8 Name: CreateRentalRequest_UPSAdmin.c(11) Error -26377 No match found for the requested parameter "c_RequetsToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 byte_8 ID: 9 Name: CreateEmergencyRentalRequest.c(13) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 10 Name: CreateEmergencyRentalRequest.c(13) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 11 Name: CreateEmergencyRentalRequest.c(13) Error -26377 No match found for the requested parameter "c_RequetsToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 byt_11 ID: 12 Name: Action.c(11) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 13 Name: Action.c(11) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 14 Name: Action.c(11) Error -26377 No match found for the requested parameter "c_RequetsToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 bytes. The total length o_14 ID: 15 Name: Action.c(13) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" ID: 16 Name: Action.c(13) Error -27789 Proxy "proxy.njc.ups.com" failed to connect to server "test.upssupplierdirectconnect.com" -- returned status code 407 authenticationrequired ID: 17 Name: Action.c(13) Error -26377 No match found for the requested parameter "c_RequetsToken". Either the specified boundaries were not found in the response or the matched text is longer than current max html parameter size of 999999 bytes. The total length o_17 Gathering Run statistics closing session SLA report: calculating SLA SLA calculation done WholeRunRules : 6 ================================ Transaction Name : 01_CreateEmergencyRequest_Login Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ ================================ Transaction Name : 01_CreateRentalReuqest_Login Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ ================================ Transaction Name : 01_DeclineRequest_Login Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ ================================ Transaction Name : 01_SearchAllRequests_Login Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ ================================ Transaction Name : 02_SearchAllRequest_Rental_ManageRequest Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ ================================ Transaction Name : 03_CreateEmergencyRequest_ClickNewEmergencyRequest Percentile : 90 Full Name : Transaction Response Time (Percentile) Measurement : PercentileTRT Goal Value : 200 Actual value : 0 status : NoData ================================ TimeRangeRules : 0 saving RunReport.xml to C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\RunReport.xml saving SLA.xml to C:\Program Files\Jenkins\UFT_EntAutomation_N1\workspace\jenkinsmaster-5\ENT\EntAutomation\Performance_Jobs\Test_Controller\34cccd\SLA.xml closing analysis session time passed: 00::00:00:50 analysis report generator finished Error: Action.c(16) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" Error: total number of errors: 1 Error(s) summary: 0 ignored , 1 errors Error summary: 1 : Action.c(16) Error -26624 HTTP Status-Code=407 (authenticationrequired) for "https//test.upssupplierdirectconnect.com/Account/Login" Error: Test FAILED. 1 errors occurred during scenario execution. Test result: Failed 28/06/2019 11:34:41 Test complete: D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs ------------------------------------------------------------------------------------------------------- Cleaning up the environment... ================================================ Run status: Job failed, total tests: 1, succeeded: 0, failures: 1, errors: 0 Failed : D:\LRC_Test App\SDC_Scripts\SDC_Scenario2.lrs ================================================ Build step 'Execute Micro Focus tests from file system' changed build result to FAILURE Email was triggered for: Failure - Any Sending email for trigger: Failure - Any Sending email to: rdasari@ups.com gsureka@ups.com Finished: FAILURE